LO 5-3820-241-12
Table 1. Lubricant Table For Pneumatic Drill
Lubricant
Temperature
Interval
Man-hour
Range
Capacity
Mil. Symbol
50 H
Above +
F
OE/HDO 30
2 qt (1 89 I) (tram motor)
MIL-L-2104
(-9C)
50 H
GO 8OW/90
1 qt (0 95 I)
MIL-L-2105
(transmission gear housing)
1 qt (0.95 I)
50 H
(transmission brake housing)
to
F
OE/HDO 10
2 qt (1.89 I) (tram motor)
10 H
MIL-L-2104
to
C)
GO 8OW/90
1 qt (0.95 I)
50 H
MIL-L-2105
(transmission gear housing)
1 qt(0 95 I)
50 H
(transmission brake housing)
2 qt (1.89 I) (tram motor)
10 H
OEA
to
F
MIL-L-46167
to
1 qt (0.95 I)
GO 75W
50 H
MIL-L-2105
(transmission gear housing)
1 qt (0 95 I)
50H
(transmission brake housing)
All
GAA
MIL-G-10924
All
GMD
BR
All
MIL-B-1 8709
NOTES:
1.
FOR OPERATION OF EQUIPMENT IN PROTRACTED COLD TEMPERATURES BELOW
(-26C).
Remove lubricants prescribed in Table 1 for temperatures above
F (-26C). Re-lubricate with lubricants specified in
Table 1 for temperatures below -15F (-26 "C). If OEA
lubricant is
required to
meet the temperature ranges prescribed in
Table 1, OEA
lubricant is to be
used in
place of
OE/HDO-10 lubricant for all temperature ranges where OE/HDO-10 is
specified. For arctic operation, see FM 9-207.
OIL CAN POINTS. Each 50 hours lubricate shift linkage, control valve linkage, control shaft slip joints, and all
2
exposed adjusting threads with OE/HDO.
3
HYDRAULIC RESERVOIR. Each 100 hours check level.
Each 250 hours remove the 2 inch drain plug in
bottom of the reservoir, drain, flush, and refill with OE/HDO
4
HYDRAULIC OIL FILTER. Each 100 hours remove element, clean filter shell, and Install new element. After
replacement, operate hydraulic system for 5 minutes, check for leaks, check level, and bring to "FULL" mark.