TM 5-2590-512-13&P
d. Installing Auger 138 Inch Hoses
1.
Grease short shaft on hose hanger bracket (8)
with GAA grease.
2.
Install 138 inch hose assembly (10) by placing
hose hanger clamp (7) on short shaft of hose
hanger bracket (8). Install lynch pin (9)
download thru hole in short shaft on hose
hangar bracket (8). Pivot lynch pin ring (9) into
locking position.
3.
Connect 138 inch hoses (10) at bucket control
cylinder hose disconnects (11).
4.
Connect 138 Inch hoses at Auger Drive Unit
quick disconnects (12).
5.
Check for loose or open or open fittings.
Replace any hydraulic fluid lost during
installation.
NOTE
Auger will be installed at evacuation site
4-15. PREPARATION FOR BUCKET USE
NOTE
This procedure may also be performed
by the operator at the excavation site.
a. Removing Auger 138 Inch Hoses.
1.
Disconnect 138 inch hoses (10) at quick-
disconnects from bucket control cylinder hoses
(11). Use rags to keep fittings clean. Install
protective dust cap and plugs.
2.
Disconnect other end of 138 inch hose
assembly (10) from quick disconnect fittings
(12) at Auger Drive Unit (13). Use rags to
keep fittings clean. Install protective dust cap
and plugs.
3.
Unlock and remove tethered lynch pin (9)
holding hose hangar clamp(7) on hose hangar
bracket (8). Remove hose hangar clamp (7)
with hoses attached. Store and lock lynch pin
downward in short shaft on hose hangar
bracket (8). Coil hoses up for storage.
b. Installing Bucket Control Hoses.
1.
Remove two nuts (14) at hose clamp (15) and
remove the top half of clamp (15).
2.
Remove and disconnect coupled bucket control
cylinder hoses at quick fitting (18).
3.
Install top half of hose clamp (15) and nuts
(14). Tighten nuts (14) to 3-5 lb. Ft. (4-7
N.m).
4.
Connect bucket control cylinder hoses (16) to
hoses (17) coming from rear of SEE at quick
disconnect (11).
NOTE
Before starting SEE engine check for
loose or unconnected hoses and loose
fittings. Also check hydraulic fluid level
in SEE reservoir and replace hydraulic
fluid lost when hoses were installed.
4-15